MSLPA01-A1 ventilator machine price/medical ventilator price with CE approve
Delivery Time: | 5 Days |
---|
Packaging: | cheap ventilator with standard export packing |
---|---|
Brand: | MSL |
Place of Origin: | Guangdong, China (Mainland) |
Basic Info
Model No.: MSLPA01-A
Product Description
Specification of Portable New Ventilator-MSLPA01 Environmental Requirements Relative humidity: 15%~95% Ambient temperature: -18~ 50° C Atmospheric pressure: 70kPa~ 110kPa Gas source: 0.28~0.6Mpa 60I/min Power: AC110V-240V or DC12V Li-battery: 14.8 V, rechargeable 2. Classification Class IType B— By protection against electric shock. IPX4— By protection against harmful ingress of water or particulate matter. ClassIType B— By protection against electric shock. IPX4— By protection against harmful ingress of water or particulate matter.
3. Indication for Portable New Ventilator :
The patients with respiratory failure caused by central and peripheral nervous system diseases, thoracic and lung diseases, neural and muscular system diseases, circulatory system diseases.
MSL sell all kinds of Medical Equipment (Medical Device, medical ventilator, Anesthesia Machine, Disabled Equipment, Ecg Machine, Ultrasound Machine, X-Ray Machine and so on) If you have any demand, please do not hesitate to contact us. We will offer best product and best service. Specification for Portable New Ventilator -MSLPA01
Display mode | High-definition 5.7” LCD screen display |
Ventilation mode | IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH |
Ventilation parameters | Tidal volume: 50~1500ml |
Rate: 2~99bpm | |
SIMV rate:2~20bpm | |
I:E 2:1~1:8 | |
Inspiratory trigger pressure -1.0~2.0 kPa | |
PEEP: 0~2.0 kPa | |
Pressure range: 1.0~6.0 kPa | |
SIGH: 1.5 times the inspiratory time | |
Parameters for ventilation monitoring | tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure |
Security Alarm SHKtem | |
Airway pressure alarm (Oxygen Alarm) | upper limit setting range 1.0~6.0 kPa low limit setting range 0.4~2.0 kPa |
Per-minute ventilation volume alarm | upper limit setting range 3.0~30L/min low limit setting range 1.0~10L/min |
Sustained high-pressure alarm | it will give alarm when stress have consistently been higher than 2.5 kPa |
Suffocation alarm | it will give sound and light alarm if there is no tidal volume input for 15 seconds |
Power alarm | |
Power | AC 220V±10% 50Hz±1Hz UPS, Storage battery |
Mechanical Arms |